pixel

The AMP Cold Room

The AMP Freezer Cold Rooms are manufactured in our Industry in Kryoneri Industrial Area of Athens with highly accurate latest technology machinery. They are air-tight for maximum economy on energy. Certified with CE 89/106 EN13241-1 (EN 89/106 / EK).

psiktikos thalamos small Small

Thermal insulation

up to 0 °C for chiller and up to -45 °C for freezer

Energy lossless

The panels seal tightly for ensured cooling energy

Highly expandable

Expandable by 50 cm at the length and width

Certified

Certified with CE 89/106 EN13241-1 (EN 89/106 / EK)

epaggelmatiko cygeio ualamos panel eswterika 800x600 0
AMP

Top quality Cold Rooms

AMP Industry manufactures top quality Cold Rooms using German raw materials as well as the German expertise. Our top quality Cold Rooms are appliable to all types of enterprises, industries such as food storing units, meat producing industries, dairies, fruit packaging, pharmaceutical industries or for personal usage. They can be either chillers or freezers and they can be manufactured according to your preferable dimensions. The frigo doors used in the cold rooms, are being produced in our factory in Kryoneri Attica, using top quality materials.

Panel connection

The panels are connected sealed with three thermal barriers with the German snap-in-system.

profil

Seal of the panels

The panels seal tightly at the connections with special sealing flanges from neoprene, perimetrically at the ceiling and the floor. Ensured cooling energy.

kunststoff connection freezer

Connection of the panels

The connection of the perimeter panels with those of the roof is made with modern (as Europe and America) that is using a packet with special flashings (backsplashes and F-shape for supporting the perimeter panels). For the connection of the side panels with the ceiling panel a step (with special machines) is created to prevent the escape of temperature-cooling.

panel room drawing

Angle panels

Four angle panels of strong construction that ease the connection of the sides as if it was a straight line.

Expandable dimensions

The dimensions of the cold rooms are expandable by 50 cm at the length and width. Special dimensions available without extra cost

Surface

Steel sheets lining of 0,55 mm thickness, with polyester anti-toxic coating NSF and protective foil.

Polyurethane insulation

Polyurethane insulation from BAYER Germany, with λR = 0,022 W/mk and density 42 – 45 kgr/m³

Frame

Frame from reinforced thick PVC in angle shape of German design covers all the thickness of the panel and is installed with the CPR system in 5 minutes with HACCP standards.

Door

Hinged and sliding doors of German technology in all dimensions with modern mechanisms

Inox surface

There is option for Inox 304 panel surface for both inside and outside of the panel, or for one of the sides (customer's choice).

Decompression valve

Every freezer room is equipped with electric decompression valve

Design

Study, design and specifications according to DIN from the Polytechnic University of Berlin. Compliance with HACCP regulation. Big saving of electrical energy.

AMP

Why AMP?

Because we guarrantee that the cold room will be SEALED, being constructed with high accuracy machines, where the required dimensions of the room are defined via computer, and a full check takes place in our facilities before loading. A test of the cold room according to DIN means that the thermal losses are zero.

Cold room open door Medium
AMP

Options

floors

Antislip floor

The plywood floors are made in Finland for cold rooms, walk-in chillers o freezers and working places, with phenol nonslip coating. They are powerful and of high resistance (2.000 kg/m2), insulating, unaffected by the humidity do not retain pollutants and are cleaned easily. They are used by all European factories.

floor heating mat

Floor heating

At the entrance of the cold room a special heated floor system with resistors under the concrete is used to allow the user to enter a clear ice-free cold room. It is a heated resistance cable, pre-assembled with a self-adhesive aluminum film, mounted on a fiberglass mesh. It is special for heating industrial and commercial floors.

cold room

Cold Room Window

You may use a insulated cold room window to your clients, to give the chance to customers to walk in the cold room and pick the stored products (for meat, cheese, fruits and vegetables). The porthole is installed on the polyurethane panel or on the door leaf.

Decompression Valves 01

Decompression Valves

The purpose of using decompression valves at cold rooms is to maintain the internal and external pressure balanced.

AMP

Customizable

You can customize your Cold Room according to your needs by choosing AMP. In this chart you can see all the available options that our factory gives you. You can also add more features to your product by contacting A. Motors office.

chiller freezer

Some of our Clients

logo mymarket 1
logo ab 1
logo lidl 1
logo sklavenitis 1
logo motor oil 1
logo aktor 1
logo stergiou 1
logo papadopoulou 1
logo elbisco 1
logo vianex 1
logo demo 1
logo costa navarino 1
logo grecotel 1

Installation Video